product

Sivacon Low Voltage Power Distribution Board (Siemens)

The SIVACON low-voltage power distribution board sets new standards as a power distribution board or Motor Control Centre (MCC) for industrial applications or in infrastructure. It is design-tested – the verification is based on testing in accordance with IEC 61439-2. The power distribution board system up to 7,000A guarantees maximized personal and system safety and, thanks to an optimal design, offers a wide range of possible uses.

More info: siemens.com/sivacon

Siemens SIVACON Technology Partner:

SRS Comcell is a preferred SIVACON Technology Partner. Sivacon Technology Partners are specifically selected by Siemens and are qualified and audited switchgear manufacturers in your area. We are licenced to Manufacture the SIVACON S8 low-voltage power distribution board including SENTRON protection, switching, measuring, and monitoring devices by Siemens. The power distribution board is tested in accordance with IEC 61439-2.

You as our customer will be able to get the bundled know-how of a technology leader from a supplier near you.

More info: siemens.com/sivacon-partner

Features and Benefits

  • Safety for human beings and plants by design verification by verification tests in accordance with IEC 61439-2.
  • Maximum personal and system safety in the event of an arcing fault in accordance with IEC/TR 61641.
  • Maximum quality assurance through design verification and routine verification.
  • Testing always carried out on the complete system with all devices.
  • Modular design allows for simple exchange or addition of functional units.
  • Single or double fronted (back to back).
  • Arc resistance level 1 to level 4 (personal and system protection) as required.
  • Rated insulation voltage: up to 1000V.
  • Rated operational voltage: up to 690V.
  • Fixed-mounted, plug-in or fully withdrawable designs.
  • Front or rear connection.
  • Top or bottom entry.
  • Internal separation Forms 1, 2b, 3a and 4b as required.
  • Rear or top main busbars positions.
  • Optional insulated busbar system to prevent the occurrence of arcing.
  • Standardized labelling system.
  • Patented wear-resistant withdrawable unit contact system.
  • Optional shutters with double-action for withdrawable units.
  • Lockable disconnected position for safe commissioning and maintenance.
  • Optional withdrawable unit coding system.
  • Arc-resistant section busbar embedding for high level of personal and system safety.
  • Main busbars rated short-time withstand current up to 150kA.
  • Vertical busbars rated short-time withstand current up to 65kA or conditional rated short-circuit current 100kA.
  • Degree of protection IP30 to IP54 as required.
  • Switchboard height is either 2000mm or 2200mm without the plinth.
  • Space saving.
  • High level of personal safety due to closed front doors in all withdrawable unit positions (connected, test and disconnected).
  • Withdrawable feeders up to 630A.
  • Withdrawable motor starters up to 250kW.
  • Convenient diagnostic possibilities through communication.